In this case, the furnace might not provide heat as needed. It is possible to lose heat from the furnace if the adjustment is made with the flue draft positioned too high. Backpressure can cause the furnace to overheat or develop other problems which might interfere with its operation.Ĭorrect adjustments on the device helps to conserve energy and fuel in the home. Setting or adjusting a barometric damper correctly reduces back pressure in the fireplace. If these are not vented safely, they can easily accumulate in the home and cause toxic air and illness. This Control is So Sensitive that Instrumentation should be Used when Adjusting the. Designed for Setting from 0.02 Inch to 0.08 Inch. 02722701 6RC 6' RC STD Barometric Draft Control for Oil Wood or Coal Residential and Commercial Field Controls 4.
RC CALIBRATED DRAFT CONTROL 10RC MANUALS
I can probably borrow and scan the manuals for both from the friend I sold it to. The fences look identical, same color, everything. It is Calibrated to Allow for Easy Adjustment to the Furnace or Boiler Manufacturer Specification. Hey, thats my old saw Sold one just like that except that it had the 30' General T-Square fence on it. A barometric damper enhances safety standards in the home too, an efficient furnace vents out gaseous wastes from combustion such as carbon dioxide and carbon monoxide. The Field RC is Furnished as Standard Equipment on Many Leading Brand of Oil or Coal-Fired Heating Equipment. Its ripping windy here today and my RC is nicely modulating to hold the system at 0.045' of water column draft. Learn when to make adjustment on the device, this will allow the oil furnace to work optimally at all times. Having recently switched to an RC, after having used a Type-M for many years, I can't believe that the Type-M is considered to be superior, as the RC is simply better in every measurable way. Make sure to move the weight correctly so as to provide effective condition that will support combustion. This is also depends on the three measurements draft over fire, draft in breech and carbon dioxide. This controls how much the draft regulator door opens to let in air. To make adjustments, move the weights along the scale to the required level. Always pay attention to carbon dioxide readings as they show how complete the combustion process takes place. These include draft over the fire, draft in breech and carbon dioxide measurements. Three sets of adjustments are made to control the device.


Check these readings so as to make correct or very precise estimates when making adjustments. There is a standard number provided by manufacturers when the burner is operating at normal temperature. Normally, these should be adjusted according to manufacturer burner’s instruction. On the surface of the device, locate the weights and scale.